Cosmo Bio USA proudly distributes MHC tetramer products from MBL (Medical & Biological Laboratories Co., Ltd.), a global pioneer in immunological reagents with over 50 years of innovation. MBL was among the first to commercialize MHC tetramers for research use, offering scientists highly stable complexes for sensitive detection of antigen-specific T cells via flow cytometry. Their tetramers are assembled from biotinylated MHC-peptide monomers and fluorochrome-conjugated streptavidin, ensuring reliable performance across applications. A standout innovation is MBL’s patented A245V mutation in the α3 domain of human and macaque MHC class I molecules, which significantly reduces non-specific CD8 binding while preserving TCR interaction—resulting in enhanced staining specificity.

MBL’s expansive tetramer lineup includes human alleles (e.g., HLA-A02:01, HLA-A24:02) and mouse alleles (e.g., H-2Kb, H-2Db), preloaded with peptides from key infectious agents (CMV, influenza, SARS-CoV-2), tumor-associated antigens (e.g., NY-ESO-1, MAGE family), and model systems (OVA, LCMV). These tetramers are available in a variety of fluorochromes—PE, APC, BV421, and more—for broad compatibility with modern flow cytometry platforms. Custom tetramer services are also available for researchers with specialized peptide or allele requirements. With MBL’s rigorously validated, precision-engineered tetramers, Cosmo Bio USA empowers North American scientists engaged in cancer immunotherapy, vaccine research, infectious disease monitoring, and autoimmune studies with high-performance tools for T cell analysis.

 

  • T-Select I-Ab human CLIP103-117 Tetramer-APC

    MBL Life Sciences

    T-Select I-Ab human CLIP103-117 Tetramer-APC

    Catalog No.(s): MBL-TS-M715-2

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,470.00
    Choose Options
  • T-Select I-Ab human CLIP103-117 Tetramer-PE

    MBL Life Sciences

    T-Select I-Ab human CLIP103-117 Tetramer-PE

    Catalog No.(s): MBL-TS-M715-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • T-Select I-Ab OVA 323-339 Tetramer-APC

    MBL Life Sciences

    T-Select I-Ab OVA 323-339 Tetramer-APC

    Catalog No.(s): MBL-TS-M710-2

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,470.00
    Choose Options
  • T-Select I-Ab OVA 323-339 Tetramer-PE

    MBL Life Sciences

    T-Select I-Ab OVA 323-339 Tetramer-PE

    Catalog No.(s): MBL-TS-M710-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • I-Ab ESAT-6 1-20 Tetramer-PE

    MBL Life Sciences

    I-Ab ESAT-6 1-20 Tetramer-PE

    Catalog No.(s): MBL-TS-M707-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • T-Select I-Ab E alpha 52-68 Tetramer-PE

    MBL Life Sciences

    T-Select I-Ab E alpha 52-68 Tetramer-PE

    Catalog No.(s): MBL-TS-M706-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • I-Ab FMLV123-141 Tetramer-PE

    MBL Life Sciences

    I-Ab FMLV123-141 Tetramer-PE

    Catalog No.(s): MBL-TS-M705-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • T-Select I-Ab MOG 35-55 Tetramer-APC

    MBL Life Sciences

    T-Select I-Ab MOG 35-55 Tetramer-APC

    Catalog No.(s): MBL-TS-M704-2

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,470.00
    Choose Options
  • T-Select I-Ab MOG35-55 Tetramer-PE

    MBL Life Sciences

    T-Select I-Ab MOG35-55 Tetramer-PE

    Catalog No.(s): MBL-TS-M704-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,470.00
    Choose Options
  • T-Select I-Ad OVA323-339 Tetramer-APC

    MBL Life Sciences

    T-Select I-Ad OVA323-339 Tetramer-APC

    Catalog No.(s): MBL-TS-M703-2

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,470.00
    Choose Options
  • T-Select I-Ad OVA323-339 Tetramer-PE

    MBL Life Sciences

    T-Select I-Ad OVA323-339 Tetramer-PE

    Catalog No.(s): MBL-TS-M703-1

    MHC Tetramers are used for the detection of antigen-specific T-cell populations. MHC-peptide tetramer complexes recognize antigen specific T-cells at the single cell level, allowing for accurate measurements of the functional immune response in cancer,...

    $1,365.00
    Choose Options
  • H-2Kd MHV M2 Tetramer-GFNKLRSTL-APC

    MBL Life Sciences

    H-2Kd MHV M2 Tetramer-GFNKLRSTL-APC

    Catalog No.(s): MBL-TS-M568-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kd MHV M2 Tetramer-GFNKLRSTL-PE

    MBL Life Sciences

    H-2Kd MHV M2 Tetramer-GFNKLRSTL-PE

    Catalog No.(s): MBL-TS-M568-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kd RSV M2 Tetramer-SYIGINNI-APC

    MBL Life Sciences

    H-2Kd RSV M2 Tetramer-SYIGINNI-APC

    Catalog No.(s): MBL-TS-M567-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kd RSV M2 Tetramer-SYIGINNI-PE

    MBL Life Sciences

    H-2Kd RSV M2 Tetramer-SYIGINNI-PE

    Catalog No.(s): MBL-TS-M567-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kb Influenza NS2 Tetramer-RTFSFQLI-APC

    MBL Life Sciences

    H-2Kb Influenza NS2 Tetramer-RTFSFQLI-APC

    Catalog No.(s): MBL-TS-M566-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kb Influenza NS2 Tetramer-RTFSFQLI-PE

    MBL Life Sciences

    H-2Kb Influenza NS2 Tetramer-RTFSFQLI-PE

    Catalog No.(s): MBL-TS-M566-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Db AdV5 E1A Tetramer-SGPSNTPPEI-APC

    MBL Life Sciences

    H-2Db AdV5 E1A Tetramer-SGPSNTPPEI-APC

    Catalog No.(s): MBL-TS-M564-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Db AdV5 E1A Tetramer-SGPSNTPPEI-PE

    MBL Life Sciences

    H-2Db AdV5 E1A Tetramer-SGPSNTPPEI-PE

    Catalog No.(s): MBL-TS-M564-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kb pBM1 Tetramer-INFDFNTI-APC

    MBL Life Sciences

    H-2Kb pBM1 Tetramer-INFDFNTI-APC

    Catalog No.(s): MBL-TS-M563-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kb pBM1 Tetramer-INFDFNTI-PE

    MBL Life Sciences

    H-2Kb pBM1 Tetramer-INFDFNTI-PE

    Catalog No.(s): MBL-TS-M563-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kb TSKB20 Tetramer-ANYKFTLV-APC

    MBL Life Sciences

    H-2Kb TSKB20 Tetramer-ANYKFTLV-APC

    Catalog No.(s): MBL-TS-M560-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kb TSKB20 Tetramer-ANYKFTLV-PE

    MBL Life Sciences

    H-2Kb TSKB20 Tetramer-ANYKFTLV-PE

    Catalog No.(s): MBL-TS-M560-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kb MAGE-A5 Tetramer-HNTQYCNL-APC

    MBL Life Sciences

    H-2Kb MAGE-A5 Tetramer-HNTQYCNL-APC

    Catalog No.(s): MBL-TS-M559-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kb MAGE-A5 Tetramer-HNTQYCNL-PE

    MBL Life Sciences

    H-2Kb MAGE-A5 Tetramer-HNTQYCNL-PE

    Catalog No.(s): MBL-TS-M559-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Kb MAGE-AX 169-176 Tetramer-LGITYDGM-APC

    MBL Life Sciences

    H-2Kb MAGE-AX 169-176 Tetramer-LGITYDGM-APC

    Catalog No.(s): MBL-TS-M558-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Kb MAGE-AX 169-176 Tetramer-LGITYDGM-PE

    MBL Life Sciences

    H-2Kb MAGE-AX 169-176 Tetramer-LGITYDGM-PE

    Catalog No.(s): MBL-TS-M558-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options
  • H-2Db MimA2 Tetramer-YAIENYLEL-APC

    MBL Life Sciences

    H-2Db MimA2 Tetramer-YAIENYLEL-APC

    Catalog No.(s): MBL-TS-M557-2

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,575.00
    Choose Options
  • H-2Db MimA2 Tetramer-YAIENYLEL-PE

    MBL Life Sciences

    H-2Db MimA2 Tetramer-YAIENYLEL-PE

    Catalog No.(s): MBL-TS-M557-1

    Anti-mouse CD8 clone choice is critical when mouse MHC I tetramers, as some clones, including 53-6.7, lead to high background staining of all CD8+ T cells, rather than the antigen-specific ones. For best results, clone KT15, available from MBL...

    $1,470.00
    Choose Options